So today I will share and discuss the installation of HyperWorks on Windows XP x64. Hope that this will also work on other Windows including Window Vista (32 & 64 bit) and Windows 7 (32 & 64 bit). Before installation make sure that you are logged on with Administrator account because You need administrator permissions to complete this setup.

The installation will complete in following steps:
  1. Install License Server. 
  2. Prepare license file for installation and Configure License File.
  3. Install the HyperWorks 10.
  4. Set up the environment variable.

1. Now Install License Server on your computer.
  • Open your DVD and go to Licensing Directory.
  • Double Click on Setup.exe file. This will start the installation of License Server on your Computer.
  • It will show you the Welcome screen. Click on Next.
  • Now it will ask you to choose destination location. Keep the location same as shown. ( Like : C:\Altair\licensing10.0)
  • The setup will complete the installation and ask you to Finish.
2. So we will start from the beginning with preparation of License File. To prepare and edit your license file for configuration follow the below steps :
  • Copy your license file in C:\Altair\licensing10.0\security.
  • Open your license file with notepad.
  • Type your Computer Name in First line After SERVER (Like: Server complete_name) And after port value (Like : 7788@complete_name) as shown below.
  • Save and Close the License File.
Here complete_name is my computer name. To know your computer name click here.


  • Now run the FLEXlm Utility from Start > All Program > Altair Licensing 10.0 > FLEXlm Utility
  1. Click on Config Services.
  2. Type the Service name Like: HyperWorks License Server.
  3. Click on Browse and select the Lmgrd.exe from C:\Altair\licensing10.0\security\bin\win32\lmgrd.exe
  4. Click on Browse and select the License File from C:\Altair\licensing10.0\security\altair_lic.dat
  5. Click on Browse and select the Path to save the Debug log file as shown.
  6. Check the Use Services.
  7. Check the Start Server at Power Up.
  8. Click on Save Services.
  9. Now go to Start/Stop/Reread and Click on Start Server.

Now Your License File and Server is Configured and License Server is started.

3. Now you can install the HyperWorks 10.0 on your computer and run it  without any problem.
  • Insert the HyperWorks 10.0 DVD for Windows into the DVD drive. The Altair HyperWorks installation wizard launches automatically. If not, double-click: <DVD drive letter>\setup.exe to start the installation wizard.
  • On the Welcome window, click Next.


  •  On the Choose Setup Type panel, select: Local for stand-alone local installation an click Next. (Software Server for an application server installation)
  •  If you selected Software Server, you will see a message box regarding the use of Network
    Neighborhood. Read, and then click OK to proceed.
  • On the Choose Destination Location dialog, select where HyperWorks will be installed.
  • For local installs: Verify that the path name specified in Path: is correct. The default path is
    C:\Altair\hw10.0. If needed, use the Browse button to select a different directory.
  • For license server or application server installs: Click the Browse box and find Network Neighborhood. From Network Neighborhood, locate the server name and specify the installation path.
  • Click Next.
 
  •  On the Choose Installation Type panel, select either Complete or Custom. Complete installs all HyperWorks applications. Custom allows you to choose the individual applications you want to install.
 

  • If you selected Custom, select the applications to install by activating the check box next to the
    name of the application to be installed. 
  • To de-select an application, click the check box to remove the check.  
  • Note: HyperWorks Desktop applications contain a functionality called HyperWorks Desktop Quick Launch. It automatically pre-loads the HyperWorks Desktop readers and DLLs upon machine booting time when this function is enabled. To turn it off, deselect it from the list under Custom/Desktop.

  •  The help is an HTML browser-based system that requires a proper browser to view the content.
    On Windows, the default browser will be used by HyperWorks help. If the help is deselected and not installed on this machine, you can specify the path of an existing 10.0 help installation in the window prompt, which allows applications to access help set on a different server.
 
  • Click Next to start the installation.
  • The Setup dialog indicates the components being installed.
  • At the end of the installation, the Altair installation wizard displays several information boxes.
    Read each, then click OK to continue the installation process.

  • On the InstallShield Wizard Complete dialog, click Finish to close the Altair HyperWorks
    installation wizard.
4. Set up the environment variable:
This method is commonly used to connect a local HyperWorks installation to the Altair license manager. It sets the environment variable ALTAIR_LM_LICENSE_FILE using the port@hostname syntax. Any time the license changes, only the license server(s) will need to be updated. Follow the instructions for your operating system.

Windows XP x64
1. Go to Start menu.
2. Right-click My Computer
3. Select Properties.
4. Select the Advanced tab.
5. Click Environment variables.
6. Under User Variables:, click on new and type  ALTAIR_LM_LICENSE_FILE in variable name.
7. For Value: 7788@complete_name (Replace complete_name with your computer name)

Hope that this guide will help you to install, configure and run the HyperWorks on your Windows plateform.
If have any query/feedback feel free to leave comments.

Thanks.

16 comments:

foudezic63 said...

Hello,

Thank you for your tutorial, it helped me a lot. But actually i've a problem with the FLEXim utilities, it doesn't want to start. I checked up the server status and i got this message :


lmgrd is not running: Cannot connect to license server system.
The license server manager (lmgrd) has not been started yet,
the wrong port@host or license file is being used, or the
port or hostname in the license file has been changed.
FLEXnet Licensing error:-15,10. System Error: 10061 "WinSock: Connection refused"

Therefore i'm not able to launch hyperworks. Can you help me please ?

nere427 said...

Hello,

Thank you for your help, but i have the same problem that foudezic 63 :

mgrd is not running: Cannot connect to license server system.
The license server manager (lmgrd) has not been started yet,
the wrong port@host or license file is being used, or the
port or hostname in the license file has been changed.
FLEXnet Licensing error:-15,10. System Error: 10061 "WinSock: Connection refused"

Could you help us please?

Anonymous said...

Hi you guys!

I know this is a little late, but I hope it helps anyway. CAD helper forgot to include one very impt step. Copy lmgrd & altair_lm from MAGNITUDE\Altair\hw10.0\security\win32 to C:\Altair\hw10.0\security\win32

Then stop and start your server again, and try to reopen hyperworks. Worked like a charm for us!

Hope it helps!

Gocha said...

Hi,

I had the same problem when installing on win7. I did all the things described in this tutorial but at the end, when trying to run the program, an error appeared. I updated the lmtools configuration and it started working! So DON'T tick "use services" & "starts server at power up", save the service, go to "Start/stop/reread" and click on start. Then a message from win appears to unblock the program, select yes and run the program. Now it should work.

Gmorales said...

Hi Gocha, I have the same problem as foudezic63 and nere427. I've read that if we use win vista, FLEXNet version, must be at least 11.4 How did you update the lmtools configurantion? Thanks.

Gmorales said...

Hi Gocha, I have the same problem as nere247 and foudezic63. I've read that if we use win vista, the LEXNet version must be at least 11.4. How did you update the lmtools configuration? Thanks.

Kottoh said...

Hello,

I have the same problem ... LMTOOLS simply not start.
to the Caribe LMTOOLS is 10.8 and it does not start, what can I do to start it?
the error is the same of friends up there.

tks

Kottoh said...

Hello,

I have the same problem ... LMTOOLS simply not start.
to the Caribe LMTOOLS is 10.8 and it does not start, what can I do to start it?
the error is the same of friends up there.

swamy said...

debug log file is missing.... i didn't find the Debug log file.

swamy said...

Hello

in the second step installation, in configuration service window.. i didn't find the Debug log file.

Anonymous said...

Any one of you know that is it possible to install Hyper Works 7.0 on windows 7, 64 bit? reply please

Anonymous said...

Hello Sir,
I tried to install HM 10 using your method but. i am not finding the correct path to License file...Os it very helpful if you can detailed installation procedure.

When I open the license file I am not able to find any thing that states "SERVER"..So please help me out in this....

EMAIL ID:bmvnay@gmail.com

vimal said...

Hello sir thanks for the installation guide. Am looking for Hyperworks v11.0 for win32bit. Where can I download it ? Please send me the links.
Thankyou

Unknown said...

Can we install Hypermesh12/13 on Windows10????

Unknown said...

Can we install Hypermesh12/13 on Windows10????

Unknown said...

i'm having the pronblem with installinh hw10.o
it shows some error flex net error 2413
install__lc.dat